Wednesday, April 29, 2015

Siemens Simotics Motor Malaysia

SIMOTICS Electric motors

EURO-TECH ASIA INTERNATIONAL SDN. BHD
visit www.eutechinternational.com
for more information.
email : sales@eutechinternational.com



SIEMENS SIMOTICS The right AC motor for every application

Unbeatable in cost-effectiveness
Our low voltage motor products cover a performance range from 0.09 to 4000 kW. Advantages of our AC motor systems are many: they are highly efficient with a positive energy balance; they come with explosion protection to meet high safety standards; and they conform to IEC or NEMA standards. The many standard features that come with every Siemens low voltage motor ensure the highest possible cost-effective operation.


Standard Motors Generation 1LE1
The new family of 1LE1 motors - one of the most compact in the world
The SIEMENS SIMOTICS new family of 1LE1 motors is also one of the most compact in the world as SIEMENS produces it employing innovative, state-of-the-art technologies. In order to achieve an optimum design, SIEMEMS uses a combination of highly conductive materials in the rotor. The results include minimized rotor losses and an excellent starting and switching behavior.
Further, SIEMENS pays special attention to environmental compatibility and the frugal use of resources in the production environment. For instance, no solvents are used in the insulation impregnation and painting.
Design and architecture of the 1LE1 motors ensure maximum flexibility and minimum associated costs when mounting and installing: Users benefit from integrated lifting eye bolts, mounting feet that can be bolted on, reinforced bearing end shields with optimum mechanical properties and terminal boxes that are easy to access. Not only this, encoders, brakes and external fans can be easily added. Stocking is also simple due to the low variance of parts enabling motor distributors to quickly respond to customer requirements.
SIEMENS 1LE1 motors with aluminum frame are suitable for a wide range of standard drive tasks in the industrial environment. As a result of their especially low weight, they are predestined for pump, fan and compressor applications. However, they are also admirably suited for conveyor technology and lifting equipment.
Technical data overview
Power and voltage range:0.55 kW to 22 kW
For all of the usual voltages
Frame sizes and types of construction:80 to 160 in all of the usual types of construction
Rated speed:750 - 3600 min-1
No. of poles:2 / 4 / 6 / 8
Efficiency classes:IE1 = Standard Efficiency
IE2 = High Efficiency
IE3 = Premium Efficiency
NEE = NEMA Energy Efficient Motors
NPE = NEMA Table 12-12 Premium Efficient Motors

Customer benefits
  • Especially user-friendly
    The well-proven terminal boxes introduced for shaft heights 100 up to 160 are now also consequentially used in the complete motor series. The 2 and 4-pole motors, frame sizes 80 and 90 go even one step further: For these motors, the terminal box is only fixed using one screw, and it can be set to any angle between 0 and 360 degrees. In addition, the terminal box has a preconfigured terminal board. This makes it significantly simpler and faster to install motors in restricted spaces, as the motor connecting cable can be routed to the motor from any direction.
  • Special export line
    The Eagle Line is available for export into NAFTA. The motors are supplied with the electrical values in compliance with EISA stamped on the rating plate.
  • More power
    Increased output power motors can be the solution if the motor must be extremely compact as there is not sufficient space available for a standard motor. With these motors, in efficiency class IE2, power ratings of a standard motor can be realized in the next smaller shaft height.

Typical applications
  • Pumps
  • Fans
  • Compressors
  • Conveyor technology
  • Lifting equipment
  • Production industry

SIEMENS 1LE1 motors with cast iron housings are especially rugged. This makes them the first choice for applications in the toughest of environmental conditions. They master dust and vibration at crushers and mixers – just the same as aggressive atmospheres in the petrochemical industry. Their design supports optimum motor cooling and offers the same handling as for the General Purpose versions.
Technical data overview
Power and voltage range:0.75 kW to 200 kW
For all of the usual voltages
Frame sizes and types of construction:100 to 315 in all of the usual types of construction
Rated speed:750 - 3600 min-1
No. of poles:2 / 4 / 6 / 8
Efficiency classes:IE1 = Standard Efficiency
IE2 = High Efficiency
IE3 = Premium Efficiency
NEE = NEMA Energy Efficient Motors
NPE = NEMA Table 12-12 Premium Efficient Motors

Customer benefits
  • The optimum motor to meet a wide range of demands
    The following lines are available for Severe Duty applications:
    • Basic Line: rugged, reliable motors for machinery construction
    • Performance Line: Motors for the process industry with reinforced bearings and a
      tougher paint finish, which can handle requirements that go beyond the Basic Line
    • Eagle Line: Motors for export into NAFTA; they fulfill ULR and CSA requirements and
      are supplied with the electrical values according to EISA stamped on the rating plate
Also here, the following applies: The 1LE1 family offers solutions for the widest range of requirements worldwide.
  • Compact type of construction
    The size of a motor frequently plays a significant role in machines. This is the reason that 1LE1 motors in IE2 and IE3 are, as a maximum, as long as their predecessors from the 1LG series in IE2.
    An additional highlight: In some instances, IE3 motors fit in the same frame as motors with IE2. It goes without saying that the efficiency classes do not differ regarding their shaft height, which is why the mechanical interface to the machine always stays the same. In turn, this facilitates an essentially straightforward efficiency upgrade to IE3 – without having to adapt the mechanical design of a machine in many cases.
  • More power
    Also in the Severe Duty area, increased power output motors can be precisely the solution if the space available for a standard motor is not sufficient. The reason for this is that these motors have the same power rating but in the next smaller shaft height.
Typical applications
  • Petrochemical industry
  • Pharmaceutical industry
  • Chemical industry
  • Printing industry
  • Process industry
  • Machinery construction
  • Pumps
  • Fans
  • Compressors

1 comment:

  1. Thanks for sharing such nice information. is there any article regarding to this topic?

    Smith
    Siemens Price List

    ReplyDelete